An Extensive Analysis Of Randomized Controlled Trials Contrasting Computed Tomography-Guided Lung Biopsies Performed At Low Versus Standard Dosages

An Extensive Analysis Of Randomized Controlled Trials Contrasting Computed Tomography-Guided Lung Biopsies Performed At Low Versus Standard Dosages

Authors

  • Anton Faculty of Medicine, Maranatha Christian University, Indonesia
  • Yusuf Faculty of Medicine, General Achmad Yani University, Indonesia

Keywords:

CT-guided, lung, biopsies, radiation

Abstract

Background: Low-Dose CT (LDCT) protocol lowers radiation dose without compromising image quality, reducing health risks. Randomized Controlled Trials have shown promising results, but further research is needed. Methods: The study followed PRISMA 2020 standards to compare LDCT-guided and SDCT-guided lung biopsies using various CT scanners. The authors meticulously searched databases and reference lists to identify relevant articles and ensure accuracy and dependability of the findings. Result: Following a thorough three-level screening process, six publications were determined to be directly related to our ongoing systematic examination. After that, the entire text was thoroughly examined, and these articles were examined even more closely. Conclusion: The study investigates radiation dose in CT scans, focusing on minimizing unnecessary exposure. Some strategies are to use iterative algorithms and reduce the tube voltage, current, and scanning time. LDCT protocols were linked to lower radiation doses, but inconsistencies in assessing image quality across studies prevent a meta-analysis.

References

Patel PR, De Jesus O. CT Scan. 2023 Jan 2. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. PMID: 33620865.

Wallace MJ, Krishnamurthy S, Broemeling LD, Gupta S, Ahrar K, Morello FA Jr.,et al. CT-guided percutaneous fine-needle aspiration biopsy of small (< or=1-cm) pulmonary lesions. Radiology. 2002;225(3):823–8.

Tian P, Wang Y, Li L, Zhou Y, Luo W, Li W. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing. J Thorac Disease. 2017;9(2):333–43.

Li Y, Yang F, Huang YY, Cao W. Comparison between computed tomography-guided core and fine needle lung biopsy: a meta-analysis. Medicine. 2022;101(9):e29016.

Heerink WJ, de Bock GH, de Jonge GJ, Groen HJ, Vliegenthart R, Oudkerk M. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol. 2017;27(1):138–48.

Maybody M, Muallem N, Brown KT, Moskowitz CS, Hsu M, Zenobi CL, et al. Autologous blood Patch Injection versus Hydrogel Plug in CT-guided lung biopsy: a prospective Randomized Trial. Radiology. 2019;290(2):547–54.

Marshall D, Laberge JM, Firetag B, Miller T, Kerlan RK. The changing face of percutaneous image-guided biopsy: molecular profiling and genomic analysis in current practice. J Vascular Interventional Radiology: JVIR. 2013;24(8):1094–103.

Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009;361(9):849–57.

Johnson JN, Hornik CP, Li JS, Benjamin DK Jr., Yoshizumi TT, Reiman RE, et al. Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation. 2014;130(2):161–7.

Liu QX, Zhou D, Han TC, Lu X, Hou B, Li MY, et al. A Noninvasive Multianalytical Approach for Lung Cancer diagnosis of patients with pulmonary nodules. Adv Sci (Weinheim Baden-Wurttemberg Germany). 2021;8(13):2100104.

Gao Y, Hua M, Lv J, Ma Y, Liu Y, Ren M, et al. Reproducibility of radiomic features of pulmonary nodules between low-dose CT and conventional-dose CT. Quant Imaging Med Surg. 2022;12(4):2368–77.

Zhang P, Liu JM, Zhang YY, Hua R, Xia FF, Shi YB. Computed tomography-guided lung biopsy: a meta-analysis of low-dose and standard-dose protocols. J Cancer Res Ther. 2021;17(3):695–701.

Zhang J, Liu ML, Liu DH, Li XQ, Lin M, Tan Y, et al. Low-dose CT with tin filter combined with iterative metal artefact reduction for guiding lung biopsy. Quant Imaging Med Surg. 2022;12(2):1359–71.

Li EL, Ma AL, Wang T, Fu YF, Liu HY, Li GC. Low-dose versus standard-dose computed tomography-guided biopsy for pulmonary nodules: a randomized controlled trial. J Cardiothorac Surg. 2023;18(1):86.

Fu YF, Li GC, Xu QS, Shi YB, Wang C, Wang T. Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol. Eur Radiol. 2020 Mar;30(3):1584-1592. doi: 10.1007/s00330-019-06464-6. Epub 2019 Nov 27. PMID: 31776740.

Grasso RF, Cazzato RL, Luppi G, D'Agostino F, Schena E, Del Vescovo R, Giurazza F, Faiella E, Beomonte Zobel B. Percutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocol. Eur Radiol. 2013 Nov;23(11):3071-6. doi: 10.1007/s00330-013-2932-9. Epub 2013 Jun 20. PMID: 23783784.

Li C, Liu B, Meng H, Lv W, Jia H. Efficacy and Radiation Exposure of Ultra-Low-Dose Chest CT at 100 kVp with Tin Filtration in CT-Guided Percutaneous Core Needle Biopsy for Small Pulmonary Lesions Using a Third-Generation Dual-Source CT Scanner. J Vasc Interv Radiol. 2019 Jan;30(1):95-102. doi: 10.1016/j.jvir.2018.06.013. Epub 2018 Aug 24. PMID: 30149997.

Meng, 2013, China, 90 Meng XX, Kuai XP, Dong WH, Jia NY, Liu SY, Xiao XS. Comparison of lung lesion biopsies between low-dose CT-guided and conventional CT-guided techniques. Acta Radiol. 2013 Oct;54(8):909-15. doi: 10.1177/0284185113485937. Epub 2013 Jul 1. PMID: 23817682.

Xie Z, Liao X, Kang Y, Zhang J, Jia L. Radiation exposure to staff in Intensive Care Unit with portable CT scanner. Biomed Res Int. 2016;2016:5656480.

Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, et al. Strategies for CT radiation dose optimization. Radiology. 2004;230(3):619–28.

Weis M, Henzler T, Nance JW Jr., Haubenreisser H, Meyer M, Sudarski S, et al. Radiation Dose Comparison between 70 kVp and 100 kVp with Spectral Beam shaping for Non-contrast-enhanced Pediatric chest computed tomography: a prospective randomized controlled study. Invest Radiol. 2017;52(3):155–62.

Li T, Xu G, Li W, Liu Y. A systematic review and meta-analysis of randomized controlled trials comparing low-dose versus standard-dose computed tomography-guided lung biopsy. J Cardiothorac Surg. 2024 May 22;19(1):297. doi: 10.1186/s13019-024-02792-x. PMID: 38778306; PMCID: PMC11110412.

Schofield R, King L, Tayal U, Castellano I, Stirrup J, Pontana F, et al. Image reconstruction: part 1 - understanding filtered back projection, noise and image acquisition. J Cardiovasc Comput Tomogr. 2020;14(3):219–25.

Staniszewska M, Chrusciak D. Iterative Reconstruction as a method for optimisation of computed tomography procedures. Pol J Radiol. 2017;82:792–7.

Geyer LL, Schoepf UJ, Meinel FG, Nance JW Jr., Bastarrika G, Leipsic JA, et al. State of the art: Iterative CT Reconstruction techniques. Radiology. 2015;276(2):339–57.

Lauzier PT, Chen GH. Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. Med Phys. 2013;40(2):021902.

Li M, Nyayapathi N, Kilian HI, Xia J, Lovell JF, Yao J. Sound out the deep colors: Photoacoustic Molecular Imaging at New depths. Mol Imaging. 2020;19:1536012120981518.

Published

2024-06-26

How to Cite

Anton, and Yusuf. 2024. “An Extensive Analysis Of Randomized Controlled Trials Contrasting Computed Tomography-Guided Lung Biopsies Performed At Low Versus Standard Dosages”. The International Journal of Medical Science and Health Research 1 (6): 33-44. https://internationalmedicaljournal.org/index.php/ijmhsr/article/view/35.